How to connect Remote RabbitMQ Server - c#

I am going to build application (Asp.net C#) to connect RabbitMQ server which is in another country.
So my question is how to connect that server.
I already installed RabbitMQ Client from NuGet Packages.
Is that needed to run RabbitMQ service in my local machine ?
Need to install RabbitMQ Server in my local machine?
From Client some of the parameters i got like
UserName, Password, HostName, Certificate with private key.
I am curious to know which are the basic steps to connect that server from my localhost application.
Can someone provide blog to refer ?
I already tried with different steps but not able to connect.
string vCertSubjectName = "CN=DevRepo, OU=IT, O=OLX, L=KTM, S=Surrey, C=UK";
ConnectionFactory factory = new ConnectionFactory();
factory.AuthMechanisms = new AuthMechanismFactory[] { new ExternalMechanismFactory() };
factory.HostName = "195.168.0.15";
factory.Port = 5673;
factory.Ssl.Certs = getCertificate(vCertSubjectName);
factory.Ssl.ServerName = System.Net.Dns.GetHostName();
factory.Ssl.Enabled = true;
factory.Ssl.Version = SslProtocols.Tls12;
IConnection connection = factory.CreateConnection();
Error coming like connection.start was never received, likely due to a network timeout."

There are very good simple examples of how to write code to send and receive messages to/from RabbitMQ on their site.
Get those examples; set up a RabbitMQ server on your local network; build the examples and verify they work. Once you know how to send/receive to/from a known instance, you can change the connection properties in your send program to point it to the RabbitMQ instance elsewhere.
I would also suggest you do a ping to the IP address of the foreign RabbitMQ server to get an idea of actual transit times. That should give you some idea if the network timeout is a valid issue.
PS. You will need a valid login and password for the RabbitMQ server before it will accept any messages from you. When you build the example programs above as long as you are on the same physical machine where RabbitMQ is running, you can use the default login and password of guest/guest. By default this will NOT work from another machine due to default security configuration of RabbitMQ.

Related

How to determine what kind of OPC server and read its item

I was provide a link of OPC server: http://192.168.2.5:54354 and was asked for read an Item value.
I am new to OPC and I assumed that my server is OPC XML-DA but when I try the sample code, it work.
But when I replace my server URL and Item name, it not work, the server address seem to be missing some part
var client = new EasyDAClient();
DAVtqResult[] vtqResults = client.ReadMultipleItems(
new ServerDescriptor { UrlString = "http://opcxml.demo-this.com/XmlDaSampleServer/Service.asmx" },
new DAItemDescriptor[]
{
"Dynamic/Analog Types/Double",
"Dynamic/Analog Types/Double[]",
"Dynamic/Analog Types/Int",
"SomeUnknownItem"
});
This one work but did not work with my Server URL: http://192.168.2.5:54354
I am not sure what /XmlDaSampleServer/Service.asmx means but I am able to connect to my sever using https://www.kassl.de/opc/explorer.shtml
Are you sure the server is XML-DA? Very few servers use this protocol in my experience. It is usually OPC DA (OPC Classic) or OPC UA.
Is there any security on the server like username and password?
From my experience, you need to be able to establish a connection with an existing client before writing any code. There could be a network or firewall issue. It appears that the server is on your local network. Can you connect to it with the Kassl client from the same server? OPC DA relies on the COM/DCOM components for communication that tend to have many issues with remote connections and firewalls.
Try the following steps:
Ping the server and make sure it replies.
Install an OPC client like Kassl or Kepware on the same Windows machine as the server and see if it can connect.
If it can, disable firewall, antivirus, etc. and see if you can connect remotely.
Check if there are any port-forwarding that needs to be done. You may want to use Wireshark to see what is happening with the data.

Test connection to the IBM MQ server every couple of minutes

We are using the IBM.XMS 8.0.0.5 .NET library to connect to the IBM MQ server and create our listeners.
But sometimes the VPN tunnel goes in sleep mode (this happens if one of our servers restarts for example). To prevent this, it is necessary to keep the VPN tunnel 'awake' by sending a network packet through the tunnel.
I looked around but IBM MQ does not have any implementation to test the connection to the server. I need some kind of 'ping' which will keep the tunnel up. But pinging is not allowed, I think they reject ICMP echos.
I am planning to create an async Task which will test the connection regularly depending on a configured interval.
Any advice on this one please?
PS Sometimes the connection falls asleep as I mentioned above. And without knowing anything the system engineer restarts the service which sends a dispose to the IBM server, even a dispose message leads to the connection being back up. And all items on the queue start being consumed by us while the service is being stopped... I need to solve this but I don't have a clue how I can do this.
EDIT
Connection is made and consumers are set up as follows:
var factoryFactory = XMSFactoryFactory.GetInstance(XMSC.CT_WMQ);
// Create WMQ Connection Factory.
var cf = factoryFactory.CreateConnectionFactory();
// Set the properties
cf.SetStringProperty(XMSC.WMQ_HOST_NAME, _parameters.IbmMqHost);
cf.SetIntProperty(XMSC.WMQ_PORT, _parameters.IbmMqPort);
cf.SetStringProperty(XMSC.WMQ_CHANNEL, _parameters.IbmMqChannel);
cf.SetIntProperty(XMSC.WMQ_CONNECTION_MODE, XMSC.WMQ_CM_CLIENT);
cf.SetStringProperty(XMSC.WMQ_QUEUE_MANAGER, _parameters.IbmMqQueueManager);
cf.SetStringProperty(XMSC.USERID, username);
cf.SetStringProperty(XMSC.PASSWORD, pw);
cf.SetIntProperty(XMSC.WMQ_CLIENT_RECONNECT_OPTIONS, XMSC.WMQ_CLIENT_RECONNECT);
// Create connection.
connection = cf.CreateConnection();
connection.ExceptionListener = ExceptionCallback;
session = connection.CreateSession(false, AcknowledgeMode.AutoAcknowledge);
destination = session.CreateQueue(queuename);
consumer = session.CreateConsumer(destination);
consumer.MessageListener = listener;
connection.Start();

Create Queue Manager in a Declared Host

In C#, using IBM WebSphere MQ, I run:
var properties = new Hashtable();
properties.Add(MQC.HOST_NAME_PROPERTY, someHostName);
var queueManager = MQQueueManager(someQueueNameManager, properties);
I get an exception:
System.Exception: Channel and Connection MUST be specified
Obviously, it wants me to specify the channel. But I don't want to specify the channel. Is it important to specify it? I mean, When I run
var queueManager = MQQueueManager(someQueueNameManager);
It works and connects to the local MQ. How can I create an MQQueueManager object that connects to a queue manager in a different host without specifying any channel? If specifying a channel is necessary, please explain why that is the case.
You need a MQI Channel (Server Conn or Server Conn & Client Conn) to connect to a remote queue manager (ie a qmgr running on a remote host) over the network. The channel connects to the qmgr and puts/gets the messages for you. For a local qmgr, you can connect in bindings mode (and that's what you have done). This mode bypasses the network stack and connects to the qmgr using shared memory and semaphores.
This is one of the basic technical concept in IBM MQ. I suggest reading the MQ primer. It's small and covers all you need to know about MQ before using it.
http://www.redbooks.ibm.com/redpapers/pdfs/redp0021.pdf

IBM.XMS MQ Listener Error 2063 or how to create connection without credentials

I'm trying to implement an MQ Listener in a windows service and I have used the xms mq consumer sample provided in the dotnet folder from the MQ Explorer installation. I am using MQ WebSphere 7.1
If I run their sample solution in console, everything works.
However, in my windows service it fails with MQ Reason Code: 2063.
I'm using these settings for my factory
cf.SetStringProperty(XMSC.WMQ_HOST_NAME, _queueHost);
cf.SetIntProperty(XMSC.WMQ_PORT, Convert.ToInt32(_queuePort));
cf.SetStringProperty(XMSC.WMQ_CHANNEL, "SYSTEM.DEF.SVRCONN");
cf.SetIntProperty(XMSC.WMQ_CONNECTION_MODE, XMSC.WMQ_CM_CLIENT_UNMANAGED);
cf.SetStringProperty(XMSC.WMQ_QUEUE_MANAGER, _queueChannel);
cf.SetIntProperty(XMSC.WMQ_BROKER_VERSION, 0);
and then this line seems to be failing
IConnection connection = cf.CreateConnection(null,null);
I don't want to provide any user credentials, is that possible?
I've tried changing the CONNECTION_MODE to bindings and getting different errors as well.
Is the sample code only working because I am running it and therefore it is using my local credentials by default? Otherwise I am using the same config in both.
The MQ XMS client is propagating the logged on user to the queue manager, then the QM checks its authority records to determine whether that user can connect and what objects it may access.
You could set the authority records to allow the user currently used to run the service, or you could set the logged on user on the windows service to match an allowed user of the queue manager, or set the MCAUSER property on the server connection channel used to connect to the queue manager, if you use client connection.
Setting the MCAUSER on the server connection channel will allow anyone who can connect to that channel to impersonate the set user, so this should be used with caution, possibly with setting appropriate channel authentication records.
References:
http://www-01.ibm.com/support/knowledgecenter/SSFKSJ_7.5.0/com.ibm.mq.msc.doc/xms_rtrouble_tips.html
https://www-01.ibm.com/support/knowledgecenter/SSFKSJ_7.5.0/com.ibm.mq.sec.doc/q010530_.htm

SQL Server Connection Issue - I can connect but other users can't

[edit] so not sure what happened, but we ended up resetting the server and turning off/on TCP/IP and Named Pipes and after a restart and updating the settings everything started working again. weirdest thing. anyways thanks for the help guys.
I'm building a C# WPF application for my job, and I'm getting a weird problem that I've been trying to figure out for the past week. The application connects to the server and imports several tables on start up. So I built it out and was testing it with no issues, but when i pass it to our testers, and everyone is getting the following errors:
Provider: Named Pipes Provider, error: 40 - Could not open a connection to SQL Server
The users are able to connect to the server through other methods (SSMS/Excel VBA), but just through the application it won't work.
I've checked the following:
Remote connections enabled
TCP/IP connections enabled
Firewall settings are the exact same across all users (me included)
application is compiled as 32 bit (saw this in another thread)
We're using SQL Server 2008 and I've tried several connection strings/methods.
below is the code I'm using to connect:
public void Open_DB_Conn(string Connection_Str)
{
try
{
Sql_Conn = new SqlConnection(Conn_Str);
Sql_Conn.Open();
}
catch (Exception e)
{
MessageBox.Show(string.Format("Error Message:{0} Conn String: {1}",e.Message,Conn_Str));
}
}
Below is my connection string (this is just one of many iterations I've used trying to get it working):
Data Source=IP Address;Initial Catalog=DB_Name;User ID=LOGIN;Password=PWD
Anyone know why I would be the only one able to get it to work and that the users are able to login to the server using other applications without a problem? They use it for logging their excel VBA scripts and there aren't any issues there.
Try this - it may be your answer
"The error is reported by client library. While your server is listeing on remote TCP, client will still try TCP and NP connection in order. So the error client behavior is expected. From what you have described, I believe that even though you enabled the remote TCP connection on the XPSP2 machine, you didn't make the TCP listening port an exception of XPSP2 personal firewall. You should follow steps below to resolve this issue.
check the SQL Server Errorlog to make sure SQL Server is now listening on TCP/IP and confirm which port it is listening on. Usually 1433. In the Errorlog, you will see several lines that discuss what SQL Server is listening on. Below is an example:
2006-01-04 01:41:07.65 server SQL server listening on 10.254.1.150: 1433. <--Shows the IP Address and the port.
2006-01-04 01:41:07.65 server SQL server listening on 127.0.0.1: 1433. <--Shows another IP Address and the port.
2006-01-04 01:41:07.69 server SQL server listening on TCP, Shared Memory, Named Pipes.
2006-01-04 01:41:07.69 server SQL Server is ready for client connections
2, Make sure on Windows XP that the firewall is not blocking that port.
3, go to your client machine and run the client network configuration tool (cliconfg.exe) Make sure TCP/IP is enabled, click properties and make sure the port number is the same one as SQL Server is listening on. Here you can enable NP or disable client NP as well.
Once both the client and the server are using TCP/IP with the same port number and the firewall on server machines is not blocked, you should be able to connect.
Hope this helps."
(Ref: http://social.technet.microsoft.com/Forums/sqlserver/en-US/c488cf76-2515-440f-b3f8-9cfad689c5b6/named-pipes-provider-error-40-could-not-open-a-connection-to-sql-server?forum=sqldataaccess)
You have to configured your SQl server so that other IP can connect it for that you have to gone through mentioned link
Configure SQL server
What authentication are you using for the SQL Server? Windows Authentication or SQL Server authentication? My suggestion is to first turn on SQL Server authentication and use the sa\password to connect to the server. If you are successful, then ask the others (users of your application) to try with the same connection string. Let me know what you find out.
Be sure that the port specified in:
Data Source="IPAddress,port";Initial Catalog=DB_Name;User ID=LOGIN;Password=PWD
matches the port on your SQL Server. You can check that by going on SQL Server COnfiguration Manager and viewing TCP/IP properties.
EDIT :
It is also the case the port defined by blocked by an external firewall. And the rest Applications use other ports. Try to find out which port you can use (if indeed the are restrictions to your network)
Make sure your SQL Server instance is properly configured to use TCP using Sql Server Configuration Manager.
It is by default disabled in SQL Express, as show below.
I'd like to know more about your "Sql_Conn" class.
Also, try using this for your connection.
using (var conn = new SqlConnection(ConfigurationManager.ConnectionStrings["ConnectionString"].ConnectionString))
{
conn.Open();
using (var cmd = conn.CreateCommand())
{
string cmdText = "SELECT name FROM sys.tables"
cmd.CommandText = cmdText;
cmd.ExecuteNonQuery();
}
}

Categories