I am using .net framework 4.6.2 and visual studio 2015.I have written sample c# project and tried analyzing with sonar, I am able to run sonarqube successfully but after that in sonar server the result is empty.
find below detail description of what I have done:
Downloaded and installed sonarqube and kept in
C:\Softwares\sonarqube-6.7.4
Downloaded and installed scanner ,
C:\Softwares\sonar-scanner-cli-3.2.0
Added the path variable value
in Environment variable as :C:\Softwares\sonar-scanner-cli-3.2.0\bin
Then run the start sonar command
from:C:\Softwares\sonarqube-6.7.4\bin\windows-x86-64 which shows
process is up, SonarQube is up .
My sample solution path is :
C:\Softwares\c# sample\sample Also added sonar-project file in the
same path which contains project details such as path, key ,port,
version, language.
In the cmd window reach out to the solution path and hit sonar-scanner command
which shows Execution Success
after checking http://localhost:9000/projects?sort=-analysis_date shows zero bugs,zero Vulnerabilities and 0 code smells with passed solution name.
Can someone have an idea what is wrong or missing in this ?
adding the screenshot of cmd prompt
sonar-qube
sonar scanner
Thanks,
You need to use the Scanner for MSBuild to analyze C# (or VB.NET), not the Scanner CLI.
The documentation is here.
What does this error message mean? What could I do to correct this issue?
AssemblyInfo.cs exited with code 9009
The problem is probably happening as part of a post-build step in a .NET solution in Visual Studio.
Did you try to give the full path of the command that is running in the pre- or post-build event command?
I was getting the 9009 error due to a xcopy post-build event command in Visual Studio 2008.
The command "xcopy.exe /Y C:\projectpath\project.config C:\compilepath\" exited with code 9009.
But in my case it was also intermittent. That is, the error message persists until a restart of the computer, and disappears after a restart of the computer. It is back after some remotely related issue I am yet to discover.
However, in my case providing the command with its full path solved the issue:
c:\windows\system32\xcopy.exe /Y C:\projectpath\project.config C:\compilepath\
Instead of just:
xcopy.exe /Y C:\projectpath\project.config C:\compilepath\
If I do not have the full path, it runs for a while after a restart, and then stops.
Also as mentioned on the comments to this post, if there are spaces in full path, then one needs quotation marks around the command. E.g.
"C:\The folder with spaces\ABCDEF\xcopy.exe" /Y C:\projectpath\project.config C:\compilepath\
Note that this example with regards to spaces is not tested.
Error Code 9009 means error file not found. All the underlying reasons posted in the answers here are good inspiration to figure out why, but the error itself simply means a bad path.
It happens when you are missing some environment settings for using Microsoft Visual Studio x86 tools.
Therefore, try adding as a first command in your post-build steps:
For Visual Studio 2010 use:
call "$(DevEnvDir)..\Tools\vsvars32.bat"
As #FlorianKoch mentioned in comments, for VS 2017 use:
call "$(DevEnvDir)..\Tools\VsDevCmd.bat"
It should be placed before any other command.
It will set environment for using Microsoft Visual Studio x86 tools.
Most probably you have space in your resultant path.
You can work around this by quoting the paths, thus allowing spaces. For example:
xcopy "$(SolutionDir)\Folder Name\File To Copy.ext" "$(TargetDir)" /R /Y /I
Had the same variable after changing PATH variable from Environmental Variables in Win 7. Changing back to default helped.
I have had the error 9009 when my post build event script was trying to run a batch file that did not exist in the path specified.
My exact error was
The command "iscc /DConfigurationName=Debug "C:\Projects\Blahblahblah\setup.iss"" exited with code 9009.
9009 means file not found, but it actually couldn't find the "iscc" part of the command.
I fixed it by adding ";C:\Program Files\Inno Setup 5 (x86)\" to the system environment variable "path"
In my case I had to "CD" (Change Directory) to the proper directory first, before calling the command, since the executable I was calling was in my project directory.
Example:
cd "$(SolutionDir)"
call "$(SolutionDir)build.bat"
I caused this error to happen when I redacted my Path environment variable. After editing, I accidentally added Path= to the beginning of the path string. With such a malformed path variable, I was unable to run XCopy at the command line (no command or file not found), and Visual Studio refused to run post-build step, citing error with code 9009.
XCopy commonly resides in C:\Windows\System32. Once the Path environment variable allowed XCopy to get resolved at DOS prompt, Visual Studio built my solution well.
If the script actually does what it needs to do and it's just Visual Studio bugging you about the error you could just add:
exit 0
to the end of you script.
Check the spelling. I was trying to call an executable but had the name misspelled and it gave me the exited with code 9009 message.
Another variant:
today I call python interpreter from cron in win32 and take ExitCode (%ERRORLEVEL%) 9009, because system account used by cron don't have path to Python directory.
The problem in my case occurred when I tried to use a command on the command-line for the Post-build event in my Test Class Library. When you use quotation marks like so:
"$(SolutionDir)\packages\NUnit.Runners.2.6.2\tools\nunit" "$(TargetPath)"
or if you're using the console:
"$(SolutionDir)\packages\NUnit.Runners.2.6.2\tools\nunit-console" "$(TargetPath)"
This fixed the issue for me.
tfa's answer has been downvoted, but actually can cause this issue.
Thanks to hanzolo, I looked in the output window and found the following:
3>'gulp' is not recognized as an internal or external command,
3>operable program or batch file.
3>D:\dev\<filepath>\Web.csproj(4,5): error MSB3073: The command "gulp clean" exited with code 9009.
After running npm install -g gulp, I stopped getting this error. If you're getting this error in Visual Studio, check the output window and see if the issue is an unset environment variable.
Also, make sure there are no line breaks in the post build event editing window on your project. Sometimes copying the xcopy command from the web when it's multi-line and pasting it into VS will cause a problem.
I added "> myFile.txt" to the end of the line in the pre-build step and then inspected the file for the actual error.
I fixed this by simply restarting Visual Studio - I had just run dotnet tool install xxx in a console window and VS hadn't yet picked up the new environment variables and/or path settings that were changed, so a quick restart fixed the issue.
For me, disk space was low, and files that couldn't be written were expected to be present later. Other answers mentioned missing files (or misnamed/improperly referenced-by-name files)--but the root cause was lack of disk space.
For me it happened after upgrade nuget packages from one PostSharp version to next one in a big solution (~80 project).
I've got compiler errors for projects that have commands in PreBuild events.
'cmd' is not recognized as an internal or external command, operable program or batch file.
C:\Program Files (x86)\MSBuild\14.0\bin\Microsoft.Common.CurrentVersion.targets(1249,5): error MSB3073: The command "cmd /c C:\GitRepos\main\ServiceInterfaces\DEV.Config\PreBuild.cmd ServiceInterfaces" exited with code 9009.
PATH variable was corrupted becoming too long with multiple repeated paths related to PostSharp.Patterns.Diagnostics.
When I closed Visual Studio and opened it again, the problem was fixed.
Yet another variant of file not found, because of spaces in the path. In my case in the msbuild script. I needed to use HTML style &quot; strings within the exec command.
<!-- Needs quotes example with my Buildscript.msbuild file -->
<Exec Command=""$(MSBuildThisFileDirectory)\wix\wixscript.bat" $(VersionNumber) $(VersionNumberShort)"
ContinueOnError="false"
IgnoreExitCode="false"
WorkingDirectory="$(MSBuildProjectDirectory)\wix" />
Same as the other answers, in my case it was because of the missing file. To know what is the missing file, you can go to the output window and it will show you straight away what went missing.
To open the output window in Visual Studio:
Ctrl+Alt+O
View > Output
This is pretty basic, I had this problem, and embarrassing simple fail.
Application use Command line arguments, I removed them and then added them back. Suddenly the project failed to build.
Visual Studio -> Project Properties -> verify that you use 'Debug' tab (not 'Build Events' tab) -> Command Line Arguments
I used the and Post/Pre-build text area, which was wrong this case.
My solution was just simple as: have you tried turning it off and on again? So I restarted the computer and the issue was gone.
I also ran into this 9009 problem when facing an overwrite situation.
Basically, if the file already exists and you have not specified the /y switch (which automatically overwrites) this error can happen when run from a build.
Happened with a colleague. If development environment is windows and visual studio project is on C: drive.. Than make sure that visual studio is run with administrator right..
simply right click and 'Run as administrator'. You can also go to the properties of visual studio project -> Advance -> and enable 'Run as administrator'.
I had the same error caused by my post build script and I tried to run the script line by line in the command prompt. Finally I found out the root cause is I did not populate the missing information in the .nuspec file, i.e. replacing all the variables between $ and $ with the actual value, e.g. replacing $author$ with my name
Check the Output tab carefully.
That should reveal the issue reason.
(E.g. in my case it was related to a comment: '#' is not recognized as an internal or external command, operable program or batch file.)
Actually I noticed that for some reason the %windir% environment variable sometimes get erased. What worked for me was re-set the windir environment variable to c:\windows, restart VS, and that's it. That way you prevent having to modify the solution files.
At least in Visual Studio Ultimate 2013, Version 12.0.30723.00 Update 3, it's not possible to separate an if/else statement with a line break:
works:
if '$(BuildingInsideVisualStudio)' == 'true' (echo local) else (echo server)
doesn't work:
if '$(BuildingInsideVisualStudio)' == 'true' (echo local)
else (echo server)
Yet another reason:
If your pre-build event references another projects bin path and you see this error when running msbuild, but not Visual Studio, then you have to manually arrange the projects in the *.sln file (with a text editor) so that the project you are targeting in the event is built before the event's project. In other words, msbuild uses the order that projects are listed in the *.sln file whereas VS uses knowledge of project dependencies. I had this happen when a tool that creates a database to be included in a wixproj was listed after the wixproj.
I have 2 machines that have the Express version of C# on them.
On one, I can build my solution and my build events execute perfectly. On the other, no matter what is put in the event it always fails. The build output has "C:\Documents in not a valid path" or something to that effect, and points to the line in Microsoft.Common.targets that contains Exec WorkingDirectory="$(OutDir)" whether it is a pre or post build event. I have deleted the targets file along with some of the MSBuild files and then repaired .Net hoping that would fix the problem, but no luck.
Any suggestions on what to do next?
Edit: This is the error that I am getting.
"E:\Programs\Visual Studio 2008\Projects\Work\Brandcode Manager....\Tools\Versioner.exe" "E:\Programs\Visual Studio 2008\Projects\C_Sharp\kjCommonFunctions\kjCommonFunctions\Properties\AssemblyInfo.cs"
'C:\Documents' is not recognized as an internal or external command,
operable program or batch file.
The system cannot find the path specified.
C:\WINDOWS\Microsoft.NET\Framework\v3.5\Microsoft.Common.targets(895,9): error MSB3073: The command ""E:\Programs\Visual Studio 2008\Projects\Work\Brandcode Manager....\Tools\Versioner.exe" "E:\Programs\Visual Studio 2008\Projects\C_Sharp\kjCommonFunctions\kjCommonFunctions\Properties\AssemblyInfo.cs"" exited with code 1.
At a guess I would say it is missing quotes somewhere - ie folders with spaces in the name, assuming the actual path is in C:\Documents and Settings\... but would need to see the real build output and the path of your solution file to give a definative answer
Here's what I ended up figuring out.
The username for the autologon account for the computer I was using (generic logon for our shared laptops) included an ampersand (&). I think that may have been causing the problems. When I created another account on that laptop and then compiled from there both my pre & post-build events worked.
KJ