I m trying to Dial mobile phone via C# program. Below Show my Program. In this, When i Click my Dial Button it dial the number(Destination number) which i given in my program. But after one or two seconds it is disappeared & its not connect to the that destination number. Below Shows my C# code. Pls help me to solve this problem. Thank you.......
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Text;
using System.Windows.Forms;
using System.IO.Ports;
namespace WindowsApplication1
{
public partial class Form1 : Form
{
public Form1()
{
InitializeComponent();
}
private void Form1_Load(object sender, EventArgs e)
{
}
private void button1_Click(object sender, EventArgs e)
{
SerialPort sp = new SerialPort();
sp.PortName = "COM10";
sp.BaudRate = 9600;
sp.Parity = Parity.None;
sp.DataBits = 8;
sp.StopBits = StopBits.One;
sp.Handshake = Handshake.XOnXOff;
sp.DtrEnable = true;
sp.RtsEnable = true;
sp.Open();
if (!sp.IsOpen)
{
MessageBox.Show("Serial port is not opened");
return;
}
sp.WriteLine("AT" + Environment.NewLine);
sp.WriteLine("ATD=\"" + "Destination Number" + "\"" + Environment.NewLine);
}
}
}
Finally i found the solution. We should add the semi-colon to end of the destination number. then its worked.
sp.WriteLine("ATD=\"" + "Destination Number;" + "\"" + Environment.NewLine);

Increase your BaudRate to max and use this AT Command:
ATD = DestinationNumber;
This will not work with out ; as the system will think you are taking a data call and not a voice call.

Try moving the decleration of the 'sp' outside the method, like so:
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Text;
using System.Windows.Forms;
using System.IO.Ports;
namespace WindowsApplication1
{
public partial class Form1 : Form
{
private SerialPort sp;
public Form1()
{
InitializeComponent();
}
private void Form1_Load(object sender, EventArgs e)
{
sp = new SerialPort();
}
private void button1_Click(object sender, EventArgs e)
{
if (sp.IsOpen)
{
sp.Close();
}
sp.PortName = "COM10";
sp.BaudRate = 9600;
sp.Parity = Parity.None;
sp.DataBits = 8;
sp.StopBits = StopBits.One;
sp.Handshake = Handshake.XOnXOff;
sp.DtrEnable = true;
sp.RtsEnable = true;
sp.Open();
if (!sp.IsOpen)
{
MessageBox.Show("Serial port is not opened");
return;
}
sp.WriteLine("AT" + Environment.NewLine);
sp.WriteLine("ATD=\"" + "Destination Number" + "\"" + Environment.NewLine);
}
}
}

Here is my working dialing cord it rings the phone
Don't knows that how to get the voice input and out put from port I'm using huwavi E173 dongle.Here is my working cord C#
SerialPort port = new SerialPort();
port.Open();
string t = port.ReadExisting();
Thread.Sleep(100);
string cmd = "ATD";
Thread.Sleep(100);
string phoneNumber = "071********";
Thread.Sleep(100);
port.WriteLine(cmd + phoneNumber + ";\r");
port.Close();

Related

SerialPort.GetPortNames() comparison for serial ports in C#

I am testing a real-time port view for serial port.
The Form1 and debug state with always false is shown below.
When Form1 is created, the COM port list is stored in recordedPorts and timer1_Tick event is generated every 100ms, the current COM port list is read and stored in presentPorts and compared with recordedPorts. If you look at the debug state picture, you can see that the result value string[] each of GetPortNames() method is the same.
I want to display COM ports in comboBox1 in real time.
However, it could not be displayed in the comboBox1.
There was a problem in string operation, so timer1_Tick event could not be operated normally.
The first question is to know why string real-time comparison is always false,
and the second is whether there is any other way to display the serial port in real time.
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using System.IO.Ports;
namespace TestSerial
{
public partial class Form1 : Form
{
string[] recordedPorts, presentPorts;
string str;
public Form1()
{
InitializeComponent();
recordedPorts = SerialPort.GetPortNames();
foreach (string PortName in recordedPorts)
{
comboBox1.Items.Add(PortName);
}
}
private void button2_Click(object sender, EventArgs e)
{
if(serialPort1.IsOpen == true)
{
serialPort1.Close();
textBox1.Text += "disconnected." + Environment.NewLine;
}
else
{
textBox1.Text += "already disconnected." + Environment.NewLine;
}
}
private void button1_Click(object sender, EventArgs e)
{
if(serialPort1.IsOpen == false)
{
serialPort1.PortName = comboBox1.SelectedItem.ToString();
serialPort1.BaudRate = 9600;
serialPort1.DataBits = 8;
serialPort1.StopBits = StopBits.One;
serialPort1.Parity = Parity.None;
//serialPort1.Open();
try
{
serialPort1.Open(); //serial port open!!!
}
catch (InvalidOperationException ex)
{
MessageBox.Show(ex.Message);
return;
}
catch (Exception ex)
{
MessageBox.Show(ex.Message);
return;
}
serialPort1.DataReceived += new SerialDataReceivedEventHandler(DataReceivedHandler);
textBox1.Text += "connected." + Environment.NewLine;
serialPort1.WriteLine("abcd\r\n");
}
else
{
textBox1.Text += "already connected." + Environment.NewLine;
}
}
private void DataReceivedHandler(object sender, SerialDataReceivedEventArgs e)
{
str = serialPort1.ReadExisting();
if(str.Length > 8)
{
textBox1.SelectedText += str + Environment.NewLine;
}
}
private void timer1_Tick(object sender, EventArgs e)
{
presentPorts = SerialPort.GetPortNames();
if (presentPorts.Count() == 0)
{
//if(comboBox1.Items.Count != 0) comboBox1.Items.Clear();
recordedPorts = presentPorts;
return;
}
if (recordedPorts != presentPorts)
{
comboBox1.DataSource = presentPorts;
recordedPorts = presentPorts;
}
}
}
}
The debug state that is always false is as follows.
Thanks to Klaus Gütter.
I resolved this question by comparing the content of the arrays instead of the array references.
Change it to the code below and it works normally.
if (!recordedPorts.SequenceEqual(presentPorts))
//if (recordedPorts != presentPorts)
{
comboBox_port.DataSource = presentPorts;
recordedPorts = presentPorts;
}

How do i pass a variable value from Console application to windows form application in C# (visual studio)

I am doing a project in which i have to send the variable data from my console application project to windows form application( i have to write that data into textbox). I am trying to pass a variable val to my form and below code is what i tried to do but passed value(num variable in windows form) is zero instead of 1 (serial.Val in console application which is passed as argument and then i am calling the form).
Can anyone please help me with that ?
This is my windows forms code:
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.IO.Ports;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using WindowsFormsApplication2;
namespace WindowsFormsApplication2
{
public partial class Serial_comm_1 : Form
{
//private static int temp;
private DateTime Datetime;
string indata;
static SerialPort COMport;
// private static int num;
public Serial_comm_1(int num)
{
InitializeComponent();
string Port_Name = "COM3"; // Store the selected COM port name to "Port_Name" varaiable
int Baud_Rate = 9600; // Convert the string "9600" to int32 9600
COMport = new SerialPort(Port_Name, Baud_Rate);
COMport.Parity = Parity.None;
COMport.StopBits = StopBits.One;
COMport.DataBits = 8;
COMport.Handshake = Handshake.None;
COMport.RtsEnable = true;
COMport.DtrEnable = true;
TextBox_Transmit_Data.Text = num.ToString();
//try to open the port
#region
try
{
COMport.Open();
textBox_System_Log.Text = "";
}
catch (UnauthorizedAccessException SerialException) //exception that is thrown when the operating system denies access
{
MessageBox.Show(SerialException.ToString());
textBox_System_Log.Text = Port_Name + Environment.NewLine + Baud_Rate;
textBox_System_Log.Text = textBox_System_Log.Text + Environment.NewLine + SerialException.ToString();
COMport.Close();
}
catch (System.IO.IOException SerialException) // An attempt to set the state of the underlying port failed
{
MessageBox.Show(SerialException.ToString());
textBox_System_Log.Text = Port_Name + Environment.NewLine + Baud_Rate;
textBox_System_Log.Text = textBox_System_Log.Text + Environment.NewLine + SerialException.ToString();
COMport.Close();
}
catch (InvalidOperationException SerialException) // The specified port on the current instance of the SerialPort is already open
{
MessageBox.Show(SerialException.ToString());
textBox_System_Log.Text = Port_Name + Environment.NewLine + Baud_Rate;
textBox_System_Log.Text = textBox_System_Log.Text + Environment.NewLine + SerialException.ToString();
COMport.Close();
}
catch //Any other ERROR
{
MessageBox.Show("ERROR in Opening Serial PORT -- UnKnown ERROR");
COMport.Close();
}
#endregion
}
private void Button_Transmit_Data_Click(object sender, EventArgs e)
{
//Local Variables
string Port_Name = "COM3"; // Store the selected COM port name to "Port_Name" variable
int Baud_Rate = 9600; // Convert the string "9600" to int32 9600
string Data = TextBox_Transmit_Data.Text; //Store the string in Textbox to variable "Data"
COMport.ReadTimeout = 3500; //Setting ReadTimeout =3500 ms or 3.5 seconds
Console.WriteLine(COMport.IsOpen);
COMport.DataReceived += new SerialDataReceivedEventHandler(DataReceivedHandler);
//Program1 prog = new Program1();
//If we are able to open the port
if (COMport.IsOpen == true)
{
COMport.WriteLine(Data); // Send Data
textBox_System_Log.Text = Port_Name + Environment.NewLine + Baud_Rate;
textBox_System_Log.Text = textBox_System_Log.Text + Environment.NewLine + Data + " Written to Port" + Environment.NewLine;
}
else
{
TextBox_Received_Data.Enabled = true; // Enable the Receive Groupbox
MessageBox.Show("Unable to Write to COM port ");
COMport.Close();
}
}
private void DataReceivedHandler(object sender, SerialDataReceivedEventArgs e)
{
SerialPort sp = (SerialPort)sender;
indata = sp.ReadLine();
this.Invoke(new EventHandler(display_data_event));
}
private void display_data_event(object sender, EventArgs e)
{
Datetime = DateTime.Now;
String time = Datetime.Hour + ":" + Datetime.Minute + ":" + Datetime.Second;
textBox_System_Log.AppendText(time + "\t\t\t" + indata + Environment.NewLine);
}
private void Form1_Load(object sender, EventArgs e)
{
}
private void label1_Click(object sender, EventArgs e)
{
}
private void textBox_Received_Data_TextChanged(object sender, EventArgs e)
{
}
private void TextBox_Transmit_Data_TextChanged(object sender, EventArgs e)
{
}
}
}
This is my trail of console application:
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using WindowsFormsApplication2;
using System.Windows.Forms;
namespace ConsoleApplication1
{
class Program1
{
private int val;
public int Val
{
get { return val; }
set { val = value; }
}
static void Main(string[] args)
{
Program1 serial = new Program1();
serial.Val = 1;
System.Windows.Forms.Application.Run(new Serial_comm_1(serial.Val));
//Serial_comm_1 serial_form1 = new Serial_comm_1(serial.Val);
}
}
}
From your app you want to start the other app:
// Create a new Process
System.Diagnostics.Process process = new System.Diagnostics.Process();
process.StartInfo = new System.Diagnostics.ProcessStartInfo();
process.StartInfo.FileName = #"C:\Projects\Temp912\bin\Debug\Temp912.exe";
process.StartInfo.Arguments = "Test Argument";
process.StartInfo.UseShellExecute = false;
process.Start();
Now from your Windows Form App, modify the Main method:
using System;
using System.Windows.Forms;
namespace Temp912
{
static class Program
{
[STAThread]
static void Main(string[] args)
{
string arg1 = "";
if ((args != null) && (args.Length > 0))
{
arg1 = args[0];
MessageBox.Show("Arg1: " + arg1, "Arg App Started With Parameter");
}
else
{
MessageBox.Show("Arg1: N/A", "Arg App Started Without Parameter");
}
Application.EnableVisualStyles();
Application.SetCompatibleTextRenderingDefault(false);
Application.Run(new Form1());
}
}
}
If you need to pass the parameter value(s) to your Main Form, expose a property or properties on your form, and set the value(s) before you launch the form.
Edit Per Question:
Form Code
public string MyProperty { get; set; } // change the data type to int or whatever
Than in Program.cs, instead of:
Application.Run(new Form1());
Do this:
// create an instance of your form
Form1 form1 = new Form1();
// set the property or properties
form1.MyProperty = arg1;
Then call:
// this is should work, I didn't test this like the other code
Application.Run(form1);

Can't control arduino analog read via Visual Studio GUI

I'm trying to make GUI for my arduino analogread. The GUI display graph and text line of the value that arduino read. I'm using zedgraph for graphing.
I need to write "on" in the serial monitor window of arduino to start the readings. it runs well. But when I try to control via GUI I made with C# Visual
Studio, the reading won't start. it says "Access to the port 'COM3' is denied".
Here's my arduino code:
void loop() {
while (Serial.available() > 0)
{
input += (char) Serial.read(); // Read in one char at a time
delay(5);
} if (input == "on")
{
myservo.write(0);
---analog reading and Serial.println arduino---
} if (input == "off")
{
myservo.write(115);
}
}
And this is my visual studio code:
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using ZedGraph;
using System.IO.Ports;
using System.Globalization;
namespace concentrationMeasurement
{
public partial class Form1 : Form
{
private SerialPort myport;
private DateTime datetime;
private string in_data;
public Form1()
{
InitializeComponent();
}
private void btnStart_Click(object sender, EventArgs e)
{
myport = new SerialPort();
myport.BaudRate = 115200;
myport.PortName = port_name.Text;
myport.Parity = Parity.None;
myport.DataBits = 8;
myport.StopBits = StopBits.One;
myport.DataReceived += myport_DataReceived;
try
{
myport.Open();
myport.WriteLine("on");
data_tb.Text = "";
}
catch (Exception ex)
{
MessageBox.Show(ex.Message,"Error");
}
}
private void myport_DataReceived(object sender, SerialDataReceivedEventArgs e)
{
in_data = myport.ReadLine();
this.Invoke(new EventHandler(displaydata_event));
}
private void displaydata_event(object sender, EventArgs e)
{
datetime = DateTime.Now;
string time = datetime.Hour + ":" + datetime.Minute + ":" + datetime.Second;
data_tb.AppendText(time + "\t\t" + in_data + "\n");
}
private void btnStop_Click(object sender, EventArgs e)
{
try
{
myport.Close();
}
catch (Exception ex2)
{
MessageBox.Show(ex2.Message, "Error");
}
}
private void save_btn_Click(object sender, EventArgs e)
{
try{
string pathfile = #"C:\Users\ajis.aprl\Documents\TA bgt\data_GUI\";
string filename = "concentration.txt";
System.IO.File.WriteAllText(pathfile + filename, data_tb.Text);
MessageBox.Show("Data has been saved to "+pathfile,"Save File");
}
catch (Exception ex3){
MessageBox.Show(ex3.Message, "Error");
}
}
private void Form1_Load(object sender, EventArgs e)
{
plotGraph();
SetSize();
}
private void plotGraph()
{
GraphPane myPane = zedGraphControl1.GraphPane;
myPane.Title.Text = "Concentration Growth";
myPane.XAxis.Title.Text = "time";
myPane.YAxis.Title.Text = "concentration";
}
}
}
So I got 2 problem here:
As I said, I can't run my analog reading via GUI, it says "Access to the port 'COM3' is denied".
in myPane.Title.Text, myPane.XAxis.Title.Tex, and myPane.YAxis.Title.Text, there's error in "Text" it says:
"Error 3 'string' does not contain a definition for 'Text' and no extension method 'Text' accepting a first argument of type 'string' could be found (are you missing a using directive or an assembly reference?)"
I googled everywhere but I can't find the answer. Please if anyone know what I'm missing. Can you tell me what's wrong with my code/logic? Thank you.

Serial Port Reading into TextBox

my eventual aim is to receive data and display it as both a graph and in individual text boxes (or something better!) the data is 2 x temperature readings and a humidity reading, for example the data sent would be "222160" etc.
However before I even tackle that I am having issues simply showing any data in a textbox. This is the code I am using; (Consists of a textbox for the UI)
using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using System.IO.Ports;
using System.Threading;
namespace WFARxSimple
{
public partial class Form1 : Form
{
string rxString;
public Form1()
{
InitializeComponent();
myport = new SerialPort();
myport.PortName = "COM5";
myport.BaudRate = 9600;
myport.Parity = Parity.None;
myport.DataBits = 8;
myport.StopBits = StopBits.One;
myport.Open();
}
private SerialPort myport;
private void DisplayText(object sender, EventArgs e)
{
showRx.AppendText(rxString);
}
private void myPort_DataReceived(object sender, SerialDataReceivedEventArgs e)
{
rxString = myport.ReadExisting();
this.Invoke(new EventHandler(DisplayText));
}
}
}
However I cannot get any data to show in my textbox.
You need, at the very least: myPort.DataReceived += myPort_DataReceived;. Do this in Form1().

Can't read the Fairbank scale weight properly

I tried to connect the scale and retrieve the weight from visual studio 2013, but it's wire that sometimes I can get the exacted weight and sometimes I couldn't. I was not sure what's wrong with the code. Can someone help? My code is listed below
using System;
using System.IO.Ports;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Text;
using System.Windows;
using System.Data.SqlClient;
using System.Collections;
using System.Threading;
namespace PortDataReceived
{
class PortData
{
public static void Main(string[] args)
{
try
{
string lineOne = "One";
string lineTwo = "Two";
char CarriageReturn = (char)0x0D;
string final = lineOne + CarriageReturn.ToString() + lineTwo + CarriageReturn.ToString();// define the hexvalues to the printer
SerialPort mySerialPort = new SerialPort("COM3");//initiate the new object and tell that we r using COM1
mySerialPort.BaudRate = 9600;
//mySerialPort.Parity = Parity.Odd;
//mySerialPort.StopBits = StopBits.Two;
//mySerialPort.DataBits = 7;
mySerialPort.Parity = Parity.Odd;
mySerialPort.StopBits = StopBits.Two;
mySerialPort.DataBits = 7;
mySerialPort.Handshake = Handshake.None;
mySerialPort.ReadTimeout = 20;
mySerialPort.WriteTimeout = 50;
mySerialPort.DtrEnable = true;
mySerialPort.RtsEnable = true;
//those r all the setting based on the scale requirement
/*foreach (string port in System.IO.Ports.SerialPort.GetPortNames())
{
Console.WriteLine(port);
}*/
while (true)
{
mySerialPort.Open();
mySerialPort.Write(final);
mySerialPort.DataReceived += new SerialDataReceivedEventHandler(DataReceivedHandler);
Console.WriteLine("Press any key to continue...");
Console.WriteLine();
Console.ReadKey();
}
//mySerialPort.Close();
}
catch (System.IO.IOException e)
{
if (e.Source != null)
Console.WriteLine("IOException source: {0}", e.Source);
throw;
}
}
private static void DataReceivedHandler(
object sender,
SerialDataReceivedEventArgs e)
{
SerialPort sp = (SerialPort)sender;
string indata = sp.ReadExisting();
Console.WriteLine("Data Received:");
Console.Write(indata);
Console.ReadKey();
}
}
}
Often with serial communication, you have to read multiple times, and concatenate each read, until you finally detect you've read the part that shows you've received it all. Detecting the end may be based on a specific count of bytes received, or it might be looking for a particular byte or sequence of bytes. But it's up to you to make that determination, and to continue reading until that condition is fulfilled. When you first read, there may be characters waiting, but the device has not sent them all yet, so you will have to read again almost immediately after your first read. You're dealing with a stream. The handler event fires when the stream starts, but it doesn't know how long the stream will flow.
This blog post discusses this and some other common serial port issues:
http://blogs.msdn.com/b/bclteam/archive/2006/10/10/top-5-serialport-tips-_5b00_kim-hamilton_5d00_.aspx